When the dashboard stops updating

A stale dashboard does not establish whether the sensor has stopped measuring. Communication may be interrupted, a component may have lost power or measurements may not yet have reached the platform. A useful specification separates three questions: was it measured, was it stored and was it transmitted?

Explore the diagram ↓

SEE THE CONNECTIONS

From the field to the full picture

Measurement, storage and transmission differMeasurement, conditional local storage, gateway and display form the chain. Connectivity loss is an event; backfill depends on verified system capability. Measurement, storage and transmission differ Process / action Data / record Event / condition Measurement Sensor power Local storage Only if supported Transmission Power and connectivity Connectivity loss Detection and response Platform and continuity Backfill only if supported Updated display Visible data gaps Storage, backup and backfill require specification review and acceptance testing. SENSE-03 · ENDI · Conceptual illustration

Diagram components and their connections. Links indicate continuation, branches or return paths.

  1. Measurement — Sensor power

  2. Local storage — Only if supported

  3. Transmission — Power and connectivity

  4. Connectivity loss — Detection and response

  5. Platform and continuity — Backfill only if supported

  6. Updated display — Visible data gaps

Measurement, conditional local storage, gateway and display form the chain. Connectivity loss is an event; backfill depends on verified system capability.

Storage, backup and backfill require specification review and acceptance testing.

Measurement, storage and transmission differ

The challenge: “backup included” is incomplete

A sensor battery does not keep a router running. An alternative cellular connection does not establish that readings are stored locally. Local memory does not establish that all readings appear immediately after reconnection. Examine the actual supplied configuration component by component.

Map the dependencies

Start at the sensor or logger and continue through the gateway, network connection and viewing platform. For each component, record its power source, communication path, local storage capability if present and behaviour when neighbouring components are unavailable.

Not every system includes every layer of backup. ENDISENSE must be specified around the selected equipment and requirements. This is a specification checklist, not a claim that a particular device includes these functions.

Test four situations separately

  1. The sensor operates but its connection to the gateway is interrupted.
  2. The gateway operates but its internet connection is unavailable.
  3. Site power is lost and each component depends on its own supply.
  4. Connectivity returns and stored readings may need reconciliation.

For each situation, define detection, notification and the alternative operating procedure. A fault in a notification path can also prevent notification of that fault. Where needed, assess an independent path or external availability check.

Review the return to service

Identify the last reading before the interruption and the first afterwards. Where stored data is recovered, distinguish measurement time from receipt time. Check time sequences, duplicates and missing intervals. Do not fill a chart in a way that suggests unrecorded measurements exist.

Plan acceptance exercises with agreed permissions, records and completion conditions. They should not require disconnecting critical equipment or exposing product to risk.

Questions for the supplier

What storage duration is supported at the chosen sampling rate, if storage exists? What backup time applies to each component, and under what conditions? How is a stale sensor shown? How are recovered readings ordered? What procedure covers the period without reliable monitoring?

Does stored data mean a remote alarm can still arrive? Not necessarily. Keeping a measurement and delivering a notification are separate capabilities.

Plan continuity scenarios with ENDISENSE and verify them against the equipment actually supplied.

Need advice for your application?

Talk to our team

Choose which services to allow. Closing without saving keeps your previous choice; first visits use essentials only.

Cookie categories

Security, sign-in, website language and privacy choices. Required for the service you request.

Usage measurement and third-party content, when configured on the website. This choice covers the group together and does not subscribe you to marketing messages.

Your choice is stored in this browser for 180 days. Changing optional-service permission reloads the page to apply it.

Cookie policy

Accessibility settings

Adjust the display to your needs. Preferences are stored in this browser and can be reset at any time.

Text size
100%

Use Tab and Shift+Tab to move between controls; Escape to close. Your device's reduced-motion preference still applies after reset. Browser zoom remains available.

Skip to main content

Accessibility statement · Report an accessibility issue